5 as interface bus connection – NORD Drivesystems BU0100 User Manual

Page 28

Advertising
background image

Technical data SK 1xxE

28

Technical modifications observed

BU 0100 GB

5.5 AS interface bus connection

The AS1 module (4 inputs / 4 outputs) corresponds to the requirements of the new AS interface according to
specification 2.1. As with the control electronics of the SK 1xxE, this assembly is entirely powered by the AS
interface. The inputs and outputs are resistant to short circuit and overload

A watchdog function has been integrated that switches the outputs current less if no communication takes
place on the AS interface line.

Up to 3 circuit elements can be queried with the inputs. A signal lamp can be activated by the output whereby
the energy is supplied from the AS interface system. The assignment for the control signals of the SK 1xxE is
included in the table below. Apart from the motor activation, up to 3 additional sensors can be connected to
M12 sockets and read. Together, they may draw max. 130 mA current.

AS1 Assignment

of M12 socket for AS Interface

Pin 1

AS1 +

Pin 2

-

Pin 3

AS1 -

Pin 4

-

Probe assignment of

the M12 sockets:

Probe connection 1

Probe connection 2

Pin 1

+24 VDC

+24 VDC

Pin 2

Probe input 3

---

Pin 3

GND

GND

Pin 4

Probe input 1

Probe input 2

Technical data

No-load current draw (Inputs = 0, Outputs = 0)

≤ 20 mA

Switching threshold of inputs

≤ 0.8 mA (low)
≥ 5 mA (high)

Voltage 20-30

VDC

Outputs 4,

electronic

Load capacity

100 mA per output, 24 VDC
(Sum of all outputs < 180 mA)

Length of power cable

E/A: max. 1.5m

Operating voltage

Via AS Interface

Operating current

< 200 mA

EMC compliance with

EN 50 081-2, EN 50 082-2

The AS1 Module 4E/4A has the following assignment:

AS Interface

Input

Ausgang

Bit 0

[OK] Output

[RUN-RIGHT] Input

Bit 1

Probe 3

[RUN-LEFT] Input

Bit 2

Probe 1

-

Bit 3

Probe 2

-

Advertising