3 electrical connection – NORD Drivesystems BU0100 User Manual

Page 7

Advertising
background image

NORDAC SK 140E

BU 0100 GB

Technical Modifications Reserved

7

2.3 Electrical connection

Power cable:

The system connection shall be performed with a cable of sufficient cross-section (max.
4 mm

2

)

Control unit:

4-pole plug with screw terminals 1.5 mm

2

(electrically separated from the system potential)

PTC resistor/brake: 3 x 2-pole screw terminals with 1.5 mm

2

(on system potential)

Cable entry:

The following are available: 1 x M25 and 1 x M12 and 1 x M16. If applicable, 1 x M12 may
already be reserved by the brake connection. Other screw connections are available, but
cannot be freely allocated.

Principle circuit diagram:

L

L

ON

1

OFF

2x

L3

L2

L1

+24V DC

OK

RUN

GND

Bremsspule

Kaltleiter oder Temperaturwächter

Brücke für langsames Abschalten

Motorklemmen

Terminal

Function

Data

Power unit

(Syst

em p

o

tent

ia

l)

L1, L2, L3

System connection

4mm

2

, (200) 380 ...480V, 50...60Hz

PE

Housing ground

4 mm

2

[L]

Bridge L

1.5 mm

2

[BR-]

Brake coil

1,5mm

2

, (105) 180V DC … 205V DC, max. 0,5A

[BR+]

Brake coil

1,5mm

2

, (105) 180V DC … 205V DC, max. 0,5A

[38] Temp1

PTC resistor

1.5 mm

2

[39] Temp2

PTC resistor

1.5 mm

2

Control unit

(e

le

c

tri

ca

llyse

p

ar

at

ed

)

[46] GND

Reference potential

1.5 mm

2

, 0 V

[45] +24 VDC

Supply voltage 24 V

1.5 mm

2

, 15...30 V, 50 mA

[22] RUN

Release signal

1.5 mm

2

, 15...30 V, ca. 2 mA

[B1] OK

Feedback, operational

1.5 mm

2

, 15...30 V, max. 50 mA

Motor terminals

Bridge for gradual switch-off

Brake coil

PTC resistor or temperature control

Advertising