COMBITOUCH™ ES SERIES • ELECTRIC INSTALLATION MANUAL • 21.

E L E C T R I C A L C O N N E C T I O N

I N S T A L L A T I O N

D A N G E R

ENSURE POWER SOURCE

MATCHES VOLTAGE STAMPED

ON APPLIANCE NAMEPLATE.

D A N G E R

To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in accordance with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.

D A N G E R

IMPROPER INSTALLATION,
ALTERATION, ADJUSTMENT,
SERVICE, OR MAINTENANCE COULD
RESULT IN SEVERE INJURY, DEATH,
OR CAUSE PROPERTY DAMAGE.

READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING
THIS EQUIPMENT.

D A N G E R

APPLIANCES WITH NO CORD
PROVIDED BY FACTORY MUST BE
EQUIPPED WITH A CORD OF
SUFFICIENT LENGTH TO PERMIT
THE APPLIANCE TO BE MOVED
FOR CLEANING.

ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.

Hard wired models:

Hard wired models must be equipped with a

country certified external allpole disconnection

switch with sufficient contact separation.
If a power cord is used for the connection of the

product an oil resistant cord like H05RN or H07RN

or equivalent must be used.

1.

An electrical wiring diagram is located behind

the control panel on the left side of the oven.

This appliance must be branch circuit protected

with proper ampacities, in accordance with the

wiring diagram.

2.

Wire size for the main incoming power to the

unit must match the minimum size listed in the

specifications applicable to the specific oven

model. For supply connections, locate the wire

size posted on the label located on the electrical

control box cover, behind the service panel.

3.

When connecting to a Delta-B (wild leg) on a

3-phase system, the wild leg must be connected

to line 3.

4.

Before operating the oven, check all cable

connections in the electrical connection area

for tightness since connections can loosen

during transport.

NOTE:

After both water and electrical connections

have been completed, operate the oven in

any cooking mode for a period of 15

minutes and recheck the main power

connections at the terminal block to make

certain they remain tight. [The need to

check motor rotation no longer applies to

the CombiTouch™ model line.]

380-415V:

To prevent an electrical shock hazard between the

appliance and other appliances or metal parts in

close vicinity, an equalization-bonding stud is

provided.

An equalization bonding lead must be connected

to this stud and the other appliances / metal parts

to provide sufficient protection against potential

difference. The terminal is marked with the

following symbol.

NOTE:

Refer to local codes for connecting

appliance to an electrical circuit that is

protected by an external GFCI outlet.

Advertising