COMBITOUCH™ ES SERIES • ELECTRIC INSTALLATION MANUAL • 26.

I N S T A L L A T I O N

W A T E R V A L V E

W A T E R D R A I N A G E

S H U T

-

O F F V A LV E S H O W N

I N T H E O F F P O S I T I O N

NOTE:

THE SHUT-OFF VALVE
MUST BE IN THE OPEN POSITION
WHEN THE OVEN IS BEING USED.

The oven must discharge through an indirect waste pipe by means of an air gap. The drain fitting is

supplied with a 1-1/2-inch (41mm) NPT thread.

A union is required. Install a 1-1/2-inch (41mm) diameter connection, drain line and clamp into place.

The drain line must always be a positive gradient

away from the Combitherm oven and not more than

12-inches (305mm) before an air gap.

NOTE:

In the U.S.A., this equipment is to be
installed to comply with the Basic Plumbing
Code of the Building Officials and Code
Administrators International, Inc. [BOCA],
and the Food Service Sanitation Manual of
the Food & Drug Administration [FDA].

If several units are to be connected to one drain

pipe, the dimensions of the

pipe must be sufficient to

allow an unobstructed

water drain system.

1-1/2" (41mm) diameter NPT
at back of oven

WASTE PIPE

1-1/2" to 2" minimum diameter

(c. 38mm to 51mm)

2" (51mm)

Air Gap

FINAL ASM, TOUCH SCREEN

COMBICLEAN

5011685

1-1/2" (41mm)
diameter connection
required

Condensate Pan
Clean Out