COMBITOUCH™ ES SERIES • ELECTRIC INSTALLATION MANUAL • 29.

I N S T A L L A T I O N

E R R O R C O D E S

Error
Code

Display Shows

When does the error

occur?

Possible reason

E20

HACCP Only - B11 Core
Temperature Probe Single
Point Fault

Error E20 is not shown in display.
Instead a probe sign with "?" is
shown as popup window. In case
the customer cooks in time mode
during first step and during second
step switches to probe mode but has
no probe in place, the error E20 will
be shown in the error code list and
HACCP list.

Single point core temperature
probe defect or disconnected

— Clean Probe Receptacle Pins with sand paper.
— B11 Single Point Core Temperature probe with quick

connect, defective.

— B11 Single Point Core Temperature probe wires with

quick connect, disconnected.

— B11 Single Point Core Temperature probe receptacle,

defective.

— B11 Single Point Core Temperature probe receptacle

wires disconnected.

E21

N6 Cavity Probe Fault

Cavity temperature probe defect
or disconnected

— N6 Oven Cavity Temperature probe defective.
— N6 Oven Cavity Temperature connection problem.

E22

B10 Core Temperature Probe
Multipoint Fault

Multipoint core temperature probe
defect or disconnected

— B10 Multipoint Core Temperature probe defective.
— B10 Multipoint Core Temperature probe connection

problem disconnected.

E23

B4 Boiler Probe Fault

Boiler temperature probe defect
or disconnected

— B4 Boiler temperature probe defective.
— B4 probe wires connection problem.

E24

B5 Bypass Probe Fault

Bypass steam temperature probe
defect or disconnected

— B5 Bypass steam temperature probe defective.
— B5 Bypass steam temperature connection problem.

E25

B3 Condensor Probe Fault

Condensor water temperature
probe defect or disconnected

— B3 Condensor temperature probe defective.
— B3 Condensor probe connection problem.

E26

N8 Boiler Safety Temperature
Probe Fault

Steam generator heating element
protection probe defect or
disconnected

— N8 Boiler temperature probe defective.
— N8 probe connection problem.

E27

Boiler Element Temperature
High

Excess steam generator safety
probe

— Scale build up inside steam generator.
— Defective water level probe.
— Water level probe connection failure.
— N8 boiler temperature probe defective.
— N8 probe connection problem.
— Steam element contactor(s) stuck closed.

E34

Steam Generator Drain Pump
Fault

Water level in steam generator
does not drop during cleaning
program

— Scale build up inside the steam generator drain pump.
— Generator drain pump is faulty
— Connection issue at drain pump.
— No output to pump from relay board.

E35

Vent not closed

Browning valve does not close
completely

— Alignment issue between motor cam and vent motor

safety switch (micro switch).

— Fault vent valve (motor).
— Fault vent valve safety switch (micro switch).
— Wiring or connection problem.

E36

Steam Temperature High

Oven cavity temperature is too
high when operating in a steam
mode or cleaning program

— Water supply is shut off.
— Low water pressure.
— Water injection pipe obstructed.
— Water flow valve plugged or defective.
— Dual solenoid valve Y-1 obstructed or defective.
— No output to solenoid valve form relay board.

E40

B3 Condensor Probe Short to
Frame

Condensor water temperature
probe short to ground

— B3 condensor temperature probe defective.
— Probe connection problem.

E41

B4 Boiler Probe Short to
Frame

Boiler protection temperature
probe short to ground

— B4 boiler temperature probe defective.
— Probe connection problem.

CONTINUED ON NEXT PAGE