COMBITOUCH™ ES SERIES • ELECTRIC INSTALLATION MANUAL • 23.

M O B I L E E Q U I P M E N T R E S T R A I N T

I N S T A L L A T I O N

Any appliance that is not furnished with a

power supply cord but includes a set of casters

must be installed with a tether. Adequate means

must be provided to limit the movement of this

appliance without depending on or transmitting

stress to the electrical conduit. The following

requirements apply:

1.

Casters must be a maximum height of 6" (152mm).

2.

Two of the casters must be the locking type.

3.

Such mobile appliances or appliances on

mobile stands must be installed with the use

of a flexible connector secured to the

building structure.

A mounting connector for a restraining device is

located on the lower back flange of the appliance

chassis or on an oven stand, approximately

18" (457mm) from the floor. A flexible connector is

not supplied by nor is it available from the factory.

W A R N I N G

RISK OF ELECTRIC SHOCK.

Appliance must be secured

to building structure.