POSITIONING REQUIREMENTS

In order to ensure proper ventilation, a minimum

distance of at least 6-inches (152mm) must be kept from

the control panels side (left) of the oven and any

adjoining surfaces.

NOTE:

Additional clearance is needed for service access.

A minimum distance of 18-inches is strongly

recommended. If adequate service clearance is not

provided, it will be necessary to disconnect the gas, water,

and drain to move the oven with a fork lift for service

access. Charges in connection with inadequate service

access is not covered under warranty.

Allow a minimum of 4-inches (102mm) from the right

side of the oven to allow the door to open to at least a

90° angle. Fully opened, the door will extend up to a

225° angle If the oven is furnished with the retractable

door option, allow a minimum clearance of

6-1/2 inches (165mm).

Allow a minimum clearance of 4-inches (102mm) from

the back of the oven for plumbing connections.

Allow a 20-inch (500mm) clearance at the top of the

oven for free air movement and for the steam vent(s)

located at the top.

Do not install the oven adjacent to heat producing

equipment such as fryers, broilers, etc. Heat from such

appliances may cause damage to the controls of the

Combitherm. Minimum clearance recommended:

20-inches (500mm)

Place the Combitherm oven on a stable, non-combustible

level horizontal surface. For countertop models, the oven

stand must be level. Level from front-to-back and side-to-

side by means of the

adjustable legs. In

addition, the overall

height of the oven

should be positioned so the operating controls and shelves

may be conveniently reached from the front.
When placing a countertop model on an oven stand,

position the oven legs on the outside of the

positioning pins.