Alto-Shaam COMBITOUCH MN-29245 User Manual

Page 33

Advertising
background image

COMBITOUCH™ ES SERIES • ELECTRIC INSTALLATION MANUAL • 31.

I N S T A L L A T I O N

E R R O R C O D E S

Error
Code

Display Shows

Model

Mode

ES

ESG

ESI

Steam

Combination Convection

Retherm

E01

Low Water Boiler

Yes

No

No

No

To 365°F

No

E02

Control Temp High

Yes

Yes

No

No

No

No

E03

Fan Motor Error

Yes

Yes

No

No

No

No

E11

Convection Temperature High

Yes

Yes

BOILER UNITS

ONLY

No

No

No

E13

Boiler Temperature High

Yes

No

No

No

Yes

No

E15

Condensor Temperature High

Yes

Yes

No

No

To 356°F

No

E20

B11 Core Temperature Probe Single
Point Fault - HACCP only

Yes

Yes

No

No

No

No

E21

N6 Cavity Probe Fault

Yes

Yes

BOILER UNITS

ONLY

No

No

No

E22

B10 Core Temp Probe Fault

Yes

Yes

BY TIME ONLY

BY TIME ONLY

BY TIME ONLY

BY TIME ONLY

E23

B4 Boiler Probe Fault

Yes

No

No

No

No

No

E24

B5 Bypass Probe Fault

Yes

Yes

No

No

Yes

No

E25

B3 Condensor Probe Fault

Yes

Yes

Yes

No

To 356°F

No

E26

N8 Boiler Safety Temperature Probe Fault

Yes

No

No

No

No

No

E27

Boiler Element Temperature High

Yes

No

No

No

Yes

No

E34

Steam Generator Drain Pump Fault

Yes

No

No

No

No

No

E35

Vent Not Closed

Yes

Yes

Yes

(

NO BROWNING

)

Yes

(

NO BROWNING

)

Yes

(

NO BROWNING

)

Yes

(

NO BROWNING

)

E36

Steam Temperature High

Yes

No

No

No

Yes

No

E40

B3 Condensor Probe Short to Frame

Yes

Yes

No

No

To 356°F

No

E41

B4 Boiler Probe Short to Frame

Yes

No

No

No

Yes

No

E42

B5 Bypass Probe Short to Frame

Yes

Yes

No

No

Yes

No

E43

N6 Cavity Probe Short to Frame

Yes

Yes

BOILER UNITS

ONLY

No

No

No

E44

N8 Boiler Safety Temperature Probe Short
to Frame

Yes

No

No

No

Yes

No

E45

B10 Core Temperature Probe Short to Frame

Yes

Yes

BY TIME ONLY

BY TIME ONLY

BY TIME ONLY

BY TIME ONLY

E51

No Water in Boiler

Yes

No

No

No

Yes

No

E53

Fan Motor High Temperature

Yes

Yes

No

No

No

No

E55

Vent Not Open

Yes

Yes

Yes

(

NO BROWNING

)

Yes

(

NO BROWNING

)

Yes

(

NO BROWNING

)

Yes

(

NO BROWNING

)

E57

No Rinse Water

Yes

Yes

Yes

Yes

Yes

Yes

E93

Communication Error FROM Display Board

Yes

Yes

No

No

No

No

E94

Communication Error, TO Display Board

Yes

Yes

No

No

No

No

E96

Communication Error, TO RBL

Yes

Yes

No

No

No

No

E97

Communication Error, FROM RBL

Yes

Yes

No

No

No

No

When the oven malfunctions, an error code will appear in the display.

PRESS THE START ICON TO ACKNOWLEDGE THE ERROR.

The icons that begin to flash represent operational modes that are still usable.

When the oven fault is corrected, the Combitherm will return to normal Operation.