COMBITOUCH™ ES SERIES • ELECTRIC INSTALLATION MANUAL • 32.

I N S T A L L A T I O N

E R R O R C O D E S

Type of Error

Indication

Release of Error

Undervoltage

LED flashing sequence, with 1 flash per period.

Voltage of intermediate circuit is less than 250V

Overvoltage

LED flashing sequence, with 2 flashes per period.

Voltage of intermediate circuit exceeds 445V

Excess
Temperature

LED flashing sequence, with 3 flashes per period.

Temperature sensor in the power unit is more than than 93°C

Overcurrent

LED flashing sequence, with 4 flashes per period.

Blocked motor, detected by current peak monitoring from
900 rpm rotating field

Overcurrent

LED flashing sequence, with 5 flashes per period.

Intermediate circuit current exceeds 4.0A

Short-circuit

LED flashing sequence, with 6 flashes per period.

Release of interrupt at intermediate circuit current larger
than 53A

Power on

LED flashing sequence, with 7 flashes per period.

Effective mains voltage does not correspond to jumper setting
115V/230V

Watchdog

LED flashing sequence, with 8 flashes per period.

Watchdog of the microcontroller released, program crash

Motor Control Error Codes