COMBITOUCH™ ES SERIES • ELECTRIC INSTALLATION MANUAL • 30.

Error
Code

Display Shows

When does the error

occur?

Possible reason

E42

B5 Bypass Probe Short to
Frame

Bypass steam temperature probe
short to ground

— B5 bypass steam temperature probe defective
— Probe connection problem.

E43

N6 Cavity Probe Short to
Frame

Cavity temperature probe short to
ground

— N6 oven cavity temperature probe defective
— Probe connection problem.

E44

N8 Boiler Safety Temperature
Probe Short to Frame

Boiler heating element protection
probe short to ground

— N8 boiler temperature probe defective.
— Probe connection problem.

E45

B10 Core Temperature Probe
Short to Frame

Multipoint core temperature probe
short to ground

— B10 multipoint core temperature probe defective.
— Probe connection problem.

E51

No Water In Boiler

No water inside steam generator

— Water supply is shut off.
— Low water pressure.
— Generator drain cap missing or loose.
— Generator drain pump is not sealing.
— Generator drain pump elbow leaking.
— Faulty or scaled water level probe.
— Faulty or plugged dual solenoid valve assembly.
— Wiring or connection issue.
— No output to dual solenoid from relay board.

E53

Fan Motor High Temperature

Fan motor too hot

— Check LED flashes on the motor control

(See Motor Control Error Code list).

— Motor seized or defective sensor.
— Hall sensor does not detect motor rotation.

E55

Vent not open

Browning valve does not open

— Alignment issue between motor cam and vent motor

safety switch (micro switch).

— Fault vent valve (motor).
— Probe connection problem.
— Fault vent valve safety switch (micro switch).
— Wiring or connection problem.

E57

No rinse water

During rinse no water flow is
detected trough solenoid valve

— Water supply is shut off.
— Low water pressure.
— Check wiring to all components mention below.
— Flow switch dirty or defect.
— Double water solenoid valve defective (Y3.)
— Relay board, high voltage, defective.

E93

Communication Error, FROM
Display Board

Communication error between
display board and low voltage
relay board

— Check ribbon cable connections mention below.
— Ribbon cable defective.
— Relay board, low voltage, connector defective.
— Display board connector defective.

E94

Communication Error, TO
Display Board

Communication error between
display board and low voltage
relay board

— Check ribbon cable connections mention below.
— Ribbon cable defective.
— Relay board, low voltage, connector defective.
— Display board connector defective.

E96

Communication Error, TO
RBL

Communication error between
display board and low voltage
relay board

— Check ribbon cable connections mention below.
— Ribbon cable defective.
— Relay board, low voltage, connector defective.
— Display board connector defective.

E97

Communication Error, FROM
RBL

Communication error between
relay board, high voltage and
relay board, low voltage

— Check ribbon cable connections mention below.
— Ribbon cable defective
— Relay board, low voltage, connector defective.
— Relay board, high voltage, connector defective.

Motor Control Error

Internal motor control

See Motor Control Error chart on following page.

I N S T A L L A T I O N

E R R O R C O D E S