background image

Alto-Shaam now offers a variety of water filtration systems

for Combitherm®.
The CombiGuard™ 10 & 20 triple-guard water filtration

system filters dirt, sediment, and other debris as small as 1/2

micron. This system also significantly reduces chlorine

content to protect against corrosive chlorine compounds.

CombiGuard improves equipment efficiency, reduces service

requirements and extends the life of the Combitherm.

Filtration system includes one filter cartridge.
The CombiGuard™ BWS Blended Water System utilizes

reverse osmosis to remove more than 97% of the total

dissolved solids from water which can be precisely blended

with filtered and treated water.
Refer to page 6 for additional ordering information.

COMBITOUCH™ ES SERIES • ELECTRIC INSTALLATION MANUAL • 25.

I N S T A L L A T I O N

W A T E R C O N N E C T I O N S

Flush the water line at the installation site.
Install water intake filters (provided) [see figure 1] before

connecting the oven to the water supply.
A hose connector is supplied for flexible hose connection

to the COLD water source.

PIPE SEALING TAPE

(

TEFLON

®

)

MUST BE USED AT

ALL CONNECTION POINTS.

The use of a pipe sealing

compound is not recommended.

WAT E R R E Q U I R E M E N T S

TWO (2) COLD WATER INLETS - DRINKING QUALITY

ONE

(1)

TREATED WATER INLET

:

3/4" NPT*

ONE

(1)

UNTREATED WATER INLET

: 3/4" NPT*

LINE PRESSURE

:

30 to 90 psi

2.8 to 6.2 bar

* Can manifold off of one 3/4" line

REFER TO PUBLISHED SPECIFIC WATER REQUIREMENTS

WATER DRAIN: 1-1/2

"

CONNECTION WITH AIR GAP

NOTE:

BOTH TREATED AND UNTREATED

WATER CONNECTIONS MUST BE

CONNECTED FOR PROPER OPERATION

OF THE OVEN. BOTH CONNECTIONS

CAN BE TREATED WATER, BUT SHOULD

NEVER BE CONNECTED TO ONLY

UNTREATED WATER.

UNIONS OR FLEXIBLE LINES SHOULD

BE USED TO ALLOW FOR OVEN

MOVEMENT WHEN BEING SERVICED OR

CLEANING IS NEEDED.

REFER TO DIMENSION DRAWINGS

BEGINNING ON PAGE 7 FOR PROPER

INTAKE LOCATIONS.

Incoming cold
water connection

T connection

Cold water line
to untreated
oven connection

Treated cold
water to treated
connection on oven

ONE SUGGESTED

METHOD OF INSTALLATION

Cold water
line to filter
or treatment
system

Install water
intake filters

Fig. 1

Water Filter

COMBIGUARD™

FI-23014