Alto-Shaam COMBITOUCH MN-29245 User Manual

Page 30

Advertising
background image

COMBITOUCH™ ES SERIES • ELECTRIC INSTALLATION MANUAL • 28.

I N S T A L L A T I O N

E R R O R C O D E S

Error
Code

Display Shows

When does the error

occur?

Possible reason

E01

Low Water Boiler

Low water level in boiler

— Water supply is shut off.
— Low water pressure.
— Generator drain cap missing or loose.
— Generator drain pump is not sealing.
— Generator Drain pump elbow leaking.
— Faulty or scaled water level probe.
— Faulty or plugged dual solenoid valve assembly.
— Wiring or connection issue.
— No output to dual solenoid from relay board.

E02

Control Temperature High

Relay board surface temperature
too high

— Cooling fan on Relay board assembly is not operating.
— Cooling Fan on display board is not operating.
— Main Cooling fan is not operating.
— Cooling Fan on motor drive is not operating.
— Unit is less than 20" from a heat producing source on

its left hand side.

E03

Fan Motor Error

Fan motor does not work

— Exhaust hood is not operating properly.
— Check LED flashes on the Motor Control.
— See Motor Control Error Code list.
— Connection Issue.

E11

Convection Temperature High Excess oven temperature

Convection Mode & Combi Mode.
— Convection Oven contactor(s) stuck closed.
— N6 Oven Cavity Temperature probe defective.
— N6 Cavity Probe connection problem.
Combi Mode Only
— Insufficient water supply into oven for steam

production.

E13

Boiler Temperature High

Boiler temperature overheats

— Scale build up inside steam generator.
— B4 Probe connection problem.
— B4 probe faulty.

E15

Condensor Temperature High

Excess condensor temperature

— Untreated Water Supply Line is shut off.
— Untreated water supply line is connected to warm

water.

— B3 probe connection problem.
— B3 probe is faulty.
— Single solenoid valve Y2 obstructed or faulty.
— Wiring or connection problem.

CONTINUED ON NEXT PAGE

This section is provided for the assistance of qualified technicians only and is not intended for use by

untrained or unauthorized service personnel. If your Alto-Shaam

®

unit is not operating properly, check the

following before calling your Authorized Alto-Shaam Service Agent:

Check the power flow to the unit. Plug in outlet?

Do not attempt to repair or service the CombiOven™ beyond this point. Contact Alto-Shaam for the

nearest authorized service agent. Repairs made by any other service agents without prior authorization

by Alto-Shaam will void the warranty on the unit.

Advertising