Command line 25
Item Description
->show external-manager
Displays the information of an existing external manager
Item Description
remove external-
manager
Remove an existing external manager (VCEM) and regain local management
control of the domain.
Syntax
remove external-manager [-quiet] UserName=<username>
[MacType=<Factory-Default| User-Defined>] [MacStart=<MAC
address>] [MacEnd=<MAC address>] [WwnType=<Factory-
Default|User-Defined>] [WwnStart=<WWN address]
[WwnEnd=<WWN address>] [ServerIdType=<Factory-Default|
User-Defined>] [ServerIdStart=<ServerId address]
[ServerIdEnd=<ServerId address>]
Option
quiet
This option suppresses user confirmation prompts. This option is useful when
scripting operations.
Properties
UserName (optional) A valid external manager user name. The username can be identified using the
show external-manager command.
MacType (Optional) The type of MAC address source to use for assignment. Valid values include:
"Factory-Default" and "User-Defined".
MacStart (Required
if the MacType is
User-Defined)
The starting MAC address in a custom user-defined range. This property is only
valid if the MacType is set to "User-Defined".
MacEnd (Required if
the MacType is
User-Defined)
The ending MAC address in a custom user-defined range. This property is only
valid if the MacType is set to "User-Defined".
WwnType (Optional) The type of WWN address source to use for assignment. Valid values include:
"Factory-Default" and "User-Defined".
WwnStart (Required
if the WwnType is
User-Defined)
The starting WWN address in a custom user-defined range.
WwnEnd (Required if
the WwnType is
User-Defined)
The ending WWN address in a custom user-defined range.
ServerIdType
(Optional)
The type of the virtual serial number source. When server profiles are created,
the virtual serial numbers and UUID values are allocated from the specified pool
source.
ServerIdStart
(Required if Type
is User-Defined)
The starting serial number in a user-defined range. This property is only valid for
user-defined serial number types.
ServerIdEnd
(Required if Type
is User-Defined)
The ending serial number in a user-defined range. This property is only valid for
user-defined serial number types.
Examples
->remove external-manager UserName=A17005068
Removes only the external management control of the VC Manager
->remove external-manager macType=Factory-Default
wwnType=Factory-Default serverIdType=Factory-Default
Releases only the profile control
- Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem