HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 42

Advertising
background image

Command line 42

Item Description

->remove network MyNetwork
Removes a network

->remove network *
Removes all networks

Item Description

set network

Modify an existing Ethernet network.

Syntax

set network <NetworkName> [-quiet] [Name=<NewName>]

[State=<Enabled|Disabled>]

[SmartLink=<Enabled|Disabled>][NativeVLAN=<Enabled|Disabled>]

[Private=<Enabled|Disabled>] [VlanId=<New VLanId>]

[ConnectionMode=<Auto|Failover>]

[VLanTunnel=<Enabled|Disabled>] [PrefSpeedType=<Auto|Custom>]

[PrefSpeed=<speed>] [MaxSpeedType=<UnRestricted|Custom>]

[MaxSpeed=<speed>]

Parameter

NetworkName

(required)

The name of an existing network to modify

Option

Quiet (optional) Suppresses user confirmation prompts during network creation and modification.

This option is used mainly in automated scripting scenarios.

Properties

Name (optional) The new name of the network
State (optional) Enables or disables the network. Valid values are "Enabled" and "Disabled".
SmartLink

(optional)

Enables or disables the SmartLink capability for a port. Valid values include
"Enabled" and "Disabled".

NativeVLAN

(optional)

Enables or disables the network to act as a native VLAN. Valid values are "Enabled"

and "Disabled". The default value is "Disabled". This property can be configured
only if it is a applied to a shared network.

Private

(optional)

Enables or disables the network to act as a private network. Valid values are

"Enabled" and "Disabled". The default value is "Disabled".

VLanID (optional) Modifies the VLAN ID of the network if it belongs to a shared uplink set that has not

been configured.

ConnectionMode

(optional)

Specifies the connection type that is formed when multiple ports are added to the
network. Valid values include "Auto" and "Failover". The default value is "Auto".

VLanTunnel

(optional)

Enables or disables VLAN tag tunneling. If Enabled, VLAN tags are passed through
the domain without any modification. If disabled, all tagged frames are discarded.
If multiple networks are configured on any server port, this option cannot be
modified.

PrefSpeedType

(Optional)

Default connection speed for any Ethernet connection attached to this network. Valid
values include "Auto" and "Custom". "Custom" allows the user to configure the

preferred speed. The default value is "Auto".

PrefSpeed

(Required if

PrefSpeedType is

'Custom')

The connection speed for any Ethernet connection attached to this network. Valid
values range from 100Mb-10Gb in 100Mb increments.

Advertising