Fabric – HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 26

Advertising
background image

Command line 26

Item Description

->remove external-manager username=A1010345

macType=Factory-Default wwnType=Factory-Default

serverIdType=Factory-Default
Removes the external manager and releases the profile control

->remove external-manager username=A19216811 mactype=User-

Defined MacStart=00-17-A4-77-00-00 MacEnd=00-17-A4-77-03-

FF wwnType=User-Defined WwnStart=50:06:0B:00:00:C2:62:00

WwnEnd=50:06:0B:00:00:C2:65:FF serverIdType=User-Defined

serverIdStart=VCX0000000 serverIdEnd=VCX00000ZZ
Removes the external manager and releases the profile control

Item Description

set external-

manager

Enable or disable an existing external manager’s control of the Virtual Connect
domain.

Syntax

set external-manager [-quiet] UserName=<username>

Enabled=<true|false>

Option

quiet

This option suppresses user confirmation prompts. This option is useful when
scripting operations.

Properties

UserName (required) A valid external manager username. The username can be identified using the

show external-manager command.

Enabled (required) Enables or disables the external manager. Valid values include "true" and

"false".

Examples

->set external-manager UserName=A17005068 Enabled=false
Disables the external manager

->set external-manager UserName=A17005068 Enabled=true
Enables the external manager

fabric

Manage Fibre Channel SAN fabrics.
Supported actions: add, help, remove, set, show

Item Description

add fabric

Add a new VC Fibre Channel SAN Fabric to the domain.

Syntax

add fabric <Name> Bay=<BayNum> Ports=<PortList>

[Speed=<Auto|1Gb|2Gb|4Gb|8Gb>] [Login=<Static|Dynamic>]

Parameter

Name (required)

A unique name for the new VC-FC Fabric to be added to the domain

Properties

Bay (required)

The specific interconnect bay number with which the fabric is associated

Advertising