Snmp-trap – HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 56

Advertising
background image

Command line 56

Item Description

->show snmp Enet
Displays SNMP configuration for only VC-Enet modules

->show snmp FC
Displays SNMP configuration for only VC-FC modules

->show snmp
Displays SNMP configuration for all VC modules

snmp-trap

Displays SNMP trap information
Supported actions: add, remove, set, show

Item Description

snmp-trap

Add a new SNMP trap destination for VC-Enet and VC-FC interconnect modules.

Syntax

add snmp-trap <TrapID> [Community=<community name string>]

Parameter

TrapID (required)

(Required) The reference name of the new trap destination to be added. The
format of the trap ID is <ENET|FC>:<Address> where the address is the IP

address of the trap destination host.

Property

Community

(optional)

The SNMP community name string for the specified trap.Default is "public". For
VC-ENET modules, maximum string length is 39. For VC-FC modules, maximum

string length is 24.

Examples

->add snmp-trap ENET:192.112.34.89 community=datacenter1
Adds a new trap destination for VC-Enet modules

->add snmp-trap FC:192.112.34.89 community=public
Adds a new trap destination for VC-FC modules

Item Description

remove snmp-trap

Remove a previously configured SNMP trap destination.

Syntax

remove snmp-trap <TrapID | *>

Parameter

TrapID (required)

(Required) The reference name of the trap destination to be removed. The format
of the trap ID is <ENET|FC>:<Address> where the address is the IP address of

the trap destination host. "*" removes all the configured SNMP traps.

Example

->remove snmp-trap ENET:192.135.67.89
Removes an SNMP trap destination for VC-Enet modules

Item Description

set snmp-trap

Modify SNMP trap configuration properties.

Syntax

set snmp-trap <TrapID> Community=<community name string>