Single-Ended I/O Module

5–6 UltraSCSI RAID Enclosure

Only when all I/O modules are the same type can an UltraSCSI RAID
subsystem function properly. The Compaq UltraSCSI controller only
supports single-ended buses. Therefore, use only single-ended I/O
modules (DS–BA35X–MN). The enclosure does not support the
following conditions:

Improperly installing a single-ended I/O module

Installing fewer than six single-ended I/O modules

Installing a termination I/O module

Installing a differential I/O module

TERMPOWER Errors

The I/O module displays a TERMPOWER status indication for both
the internal and external bus as shown in Figure 5–4.

Figure 5–4

I/O Module TERMPOWER LEDs

The nominal TERMPOWER for both buses is +5 V dc.

The green internal (C

ALLOUT

2) and external (C

ALLOUT

1)

TERMPOWER LEDs are O

N

during normal operation.

If a TERMPOWER overcurrent condition exists or there is no
TERMPOWER, the associated LED is O

FF

.

Figure C

ALLOUTS

1.

External
TERMPOWER

2.

Internal
TERMPOWER

CXO5829B