Redundant (n+4) power supply configurations, Figure 6–6 redundant power configuration, Redundant (n+4) power supply configurations –8 – HP Array Controller HSG V8.7 Software User Manual

Page 134: Figure 6–6 redundant power configuration –8, Power distribution

Advertising
background image

Power Distribution

6–8 UltraSCSI RAID Enclosure

Any one of the following power related error conditions will cause
this UltraSCSI RAID enclosure to cease operation:

Loss of the ac power source

Failure of two shelf power supplies

Failure of the ac input box

Redundant (n+4) Power Supply
Configurations

This power configuration provides more power redundancy than the
standard configuration. AC power distribution is provided over both
power buses (A and B, C

ALLOUTS

1 and 2, respectively) as shown in

Figure 6–6. Each bus has four power supplies for a total of eight.

Figure 6–6

Redundant Power Configuration

AC input box A distributes the ac power through four black cords at
the left side of the enclosure. AC input box B distributes the ac power
through four grey cords on the right side of the enclosure.

Figure C

ALLOUTS

1.

Power bus A

2.

Power bus B

CXO5797A

17

11

CXO6482B

19 20

21 22 23 24

13 14

15 16

18

7

8

9

10

12

1

2

3

4

5

6

Controller A
Controller B

EMU

PVA

Cache B

Cache A

A

B

4A

3A

2A

1A

3B

2B

1B

4B

Shelf 4

Shelf 3

Shelf 2

Shelf 1

1

2

Advertising