2–12 UltraSCSI RAID Enclosure

Fault Detection

Fault detection involves identifying errors and providing an indication
to the user for analysis. The following sections address how faults are
identified, descriptions of status LED indications, and in some cases,
possible corrective actions.

Error Detection, Reporting, and Analysis

The EMU and PVA constantly monitor the operational status of the
enclosure and its components. In some instances, automatic
corrective action implementation occurs. Status changes are indicated
to the user through a combination of LEDs, an EMU audible alarm,
and an optional maintenance terminal connected to the array
controller. Table 2–6 lists the major enclosure components and the
status items monitored by each component.

Table 2–6

Enclosure Status Monitoring

Component

Status Monitored

Enclosure

Intake air temperature

Exhaust air temperature

AC input power

Number of operational 180 W power supplies

Enclosure SCSI bus address

Power

Output of dc power supplies

DC bus voltages

Termination I/O module dc voltage

Storage devices
(disk drive
SBBs)

Control signal response

Controller-detected fault condition

Removal

Installation

EMU

Installation

PVA

Installation