Disk drive status leds, Figure 2–6 disk drive status leds, Disk drive status leds –17 – HP Array Controller HSG V8.7 Software User Manual

Page 53: Figure 2–6 disk dr, Operating the ultrascsi enclosure

Advertising
background image

Operating the UltraSCSI Enclosure

UltraSCSI RAID Enclosure 2–17

Removal of a disk drive SBB device is automatically sensed by the
array controller.

When installing a replacement device in a configured subsystem, the
array controller ensures that the replacement device type is identical
to the one removed. Only after establishing complete compatibility
can the array controller start configuring the disk drive SBB. As part
of the configuration process, the array controller will restore all data
that was on the original disk.

Disk Drive Status LEDs

Each disk drive SBB has two LEDs that display its operating status
(Figure 2–6). The green device activity LED (C

ALLOUT

1) is O

N

or

F

LASHING

whenever the disk drive SBB is active.

Figure 2–6

Disk Drive Status LEDs

The amber device fault LED (C

ALLOUT

2) F

LASHES

whenever the

array controller detects that this device has an error condition. This
LED also F

LASHES

when the array controller issues a locate

command. This LED is only O

N

or F

LASHING

when there is a device

malfunction, except when a locate command is issued.

For detailed information about the disk drive SBB status LEDs, see
Chapter 7.

Figure C

ALLOUTS

1.

Device activity LED

2.

Device fault LED

1

2

CXO4652B

Advertising