Product description, Figure 3–2 emu location, Product description –2 – HP Array Controller HSG V8.7 Software User Manual

Page 58

Advertising
background image

Environmental Monitoring Unit

3–2 UltraSCSI RAID Enclosure

Product Description

The EMU detects enclosure error conditions and configuration faults,
and then notifies the user of existing or impending failures, using one
or more of the following error reporting systems:

EMU LEDs

EMU audible alarm

Error messages on the host interface

Enclosure LEDs

The EMU (C

ALLOUT

1) mounts directly above array controller “A”

(upper bus controller) as shown in Figure 3–2.

Figure 3–2

EMU Location

In some instances [such as a blower failure, a high intake air
temperature, or a high internal enclosure (exhaust) temperature], the
EMU automatically initiates corrective action. For example, the EMU
will command the blowers to operate at high-speed to prevent
component damage due to an overtemperature condition. In a severe
case, the EMU might even turn O

FF

the enclosure power.

Figure C

ALLOUTS

1.

EMU

2.

PVA

CXO5754B

2

1

Advertising