background image

Environmental Monitoring Unit

3–28 UltraSCSI RAID Enclosure

Replacing an EMU

Complete the procedure in Table 3–9 to remove an EMU and
complete the procedure in Table 3–10 to install an EMU.

Table 3–9

Removing an EMU

1.

Clear the cache module and shut down the array controller per the
array controller documentation.

2.

If there are no expansion enclosures, go to step 3.

If there are expansion enclosures, press and hold the PVA standby
power switch (C

ALLOUT

1) on an expansion enclosure until the

master EMU initiates a power shut down of all enclosures.

3.

Press and hold the PVA standby power switch (C

ALLOUT

1) on the

master enclosure until the master EMU initiates a power shut down
on the master enclosure.

4.

If there are no expansion enclosures, go to step 5.

If there are expansion
enclosures, turn O

FF

all the

ac input boxes for each
expansion enclosure by
pressing O on each ac power
switch (C

ALLOUT

1).

5.

Turn O

FF

all the ac input

boxes for the master
enclosure by pressing O on
each ac power switch
(C

ALLOUT

1).

CXO6303A

1

1

0

CXO5488B

2

1