Server Blade Component Identification

Table 1-2: Hot-Plug SCSI Hard Drive LED Status Combinations

(1) Activity

(2) Online (3)

Fault Description

On Off

Off

Do not remove the drive. Removing a drive during
this process causes data loss.

The drive is being accessed and is not configured as
part of an array.

On Flashing

Off

Do not remove the drive. Removing a drive during
this process causes data loss.

The drive is rebuilding or undergoing capacity
expansion.

Flashing Flashing

Flashing

Do not remove the drive. Removing a drive during
this process causes data loss.

The drive is part of an array being selected by the Array
Configuration Utility.

-Or-

The Options ROMPaq is upgrading the drive.

Off

Off

Off

OK to replace the drive online if a predictive failure alert
is received and the drive is attached to an array
controller.

The drive is not configured as part of an array.

-Or-

If this drive is part of an array, a powered-on controller
is not accessing the drive.

-Or-

The drive is configured as an online spare.

Off

Off

On

OK to replace the drive online.

The drive has failed and has been placed offline.