If no, refer to table a-4 – HP ProLiant BL20p G3 Server Blade User Manual

Page 92

Advertising
background image

Server Blade Troubleshooting

Table A-4: Is the Server Blade Health LED Solid Green?

Answer Possible

Reasons Possible

Solutions

No, it is amber.

A processor is in pre-failure
condition.

A DIMM is in pre-failure condition.

One memory bank is valid, but
another bank is missing a DIMM.

One memory bank is valid, but
another bank has mismatched
DIMMs installed.

One memory bank is valid, but
another bank has an unsupported
DIMM type installed.

Do the following:

1. Remove the server blade from the

server blade enclosure.

2. With the system powered down,

remove the access panel.

3. Visually inspect the system for

damage.

4. Reseat or replace processors

and/or DIMMs.

5. Be sure that the proper connections

exist among the power converter
module, system board, SCSI
backplane, and power button/LED
board.

6. Verify that DIMMs are installed in

pairs.

7. Reinstall the access panel.

8. Reinstall and power up the server

blade.

continued

HP ProLiant BL20p Generation 3 Server Blade User Guide

A-7