Installation and Upgrade Requirements

Observe the following requirements before installing a processor in the server blade:

•

Before installing a processor in the server, processor socket 1 must always be
populated. If the processor is missing from socket 1, the system will not power
on.

•

If processors of differing speeds are installed, each processor matches the speed
of the slowest processor.

Removing a Processor and Heatsink

For information on accessing internal server blade components, refer to “Accessing
Internal Server Blade Components” in Chapter 3, “Server Blade Setup.”

IMPORTANT: The heatsink is not reusable and must be discarded if removed from the
processor after application.

Figure 4-1: Unlatching the heatsink locking levers and
removing the heatsink

4-2