LUN Configuration and Security Manager XP user guide for the XP12000/XP10000/SVS200 137

NOTE:

• Round up the value enclosed by two up arrows (

) to the nearest whole number.

• The user-specified CV capacity is expressed in blocks.
• The boundary value is expressed in kilobytes. The boundary value depends on volume

emulation types and RAID levels (see

Table 28

on page 138).

If the emulation type is other than OPEN-V

If the CV capacity unit is MB (megabytes):
To calculate the CV’s user area capacity, use the following formula. The resulting user area capacity is

expressed in kilobytes.

↑ ↑

user-specified-CV-capacity

Ч

1024

ч

capacity-of-a-slot

ч

15

Ч

capacity-of-a-slot

×

15

NOTE:

• Round up the value enclosed by two up arrows (

) to the nearest whole number.

• The user-specified CV capacity is expressed in megabytes.
• The slot capacity is expressed in kilobytes. The slot capacity depends on volume emulation

types (see

Table 29

on page 139).

To calculate the CV’s entire capacity, use the following formula. The resulting entire capacity is

expressed in megabytes.

(user-area-capacity + management-area-capacity)

÷

boundary-value

×

boundary-value

÷

1024

NOTE:

• Round up the value enclosed by two up arrows (

) to the nearest whole number.

• The user area capacity is expressed in kilobytes.
• The management area capacity is expressed in kilobytes. The management area capacity

depends on volume emulation types (see

Table 27

on page 138).

• The boundary value is expressed in kilobytes. The boundary value depends on volume

emulation types and RAID levels (see

Table 28

on page 138).

If the CV capacity unit is blocks:
To calculate the CV’s user area capacity, use the following formula. The resulting user area capacity is

expressed in kilobytes.

user-specified-CV-capacity

÷

2

NOTE:

The user-specified CV capacity is expressed in blocks.

To calculate the CV’s entire capacity, use the following formula. The resulting entire capacity is

expressed in blocks. To convert the resulting entire capacity into megabytes, divide this capacity by

2,048.

(user-specified-CV-capacity + management-area-capacity

Ч

2)

ч

(boundary-value

Ч

2)

Ч

(boundary-value

×

2)

NOTE:

• Round up the value enclosed by two up arrows (

) to the nearest whole number.

• The user-specified CV capacity is expressed in blocks.
• The management area capacity is expressed in kilobytes. The management area capacity

depends on volume emulation types (see

Table 27

on page 138).

Advertising