LUN Configuration and Security Manager XP user guide for the XP12000/XP10000/SVS200

87

CAUTION:

Before changing an iSCSI target’s host mode, HP recommends that you first back up data on

the port the iSCSI target belongs to. The operation for setting the host mode should not be destructive, but

data integrity cannot be guaranteed without a backup.

1.

Start LUN Manager. The LUN Manager pane (

Figure 15

) appears.

2.

In the tree, right-click the iSCSI target, and select Change iSCSI Target. The Change iSCSI Target pane

appears.

Figure 49

Change iSCSI Target pane

3.

To change the iSCSI target’s name, enter a new name in the Target name box.
To change the alias, enter a new alias in the Target alias box. iSCSI target aliases can include letters,

numbers, periods (.), hyphens (-), and colons (:); but cannot include double-byte characters. iSCSI

target aliases are case-sensitive. An iSCSI target alias can consist of up to 32 characters
To change the host mode (see

Table 16

), select the new host mode from the Host Mode list.

4.

If necessary, click Option, and select the host mode options. For more information about host mode

options, see

Table 17

on page 77.

Figure 50

Change iSCSI Target pane (Option selected)

NOTE:

After you click Option, the pane expands to display a list of host mode options. The No.

column indicates option numbers. Select the check box of the option you want to specify.

5.

Click OK. Changes are indicated in blue in the tree.

6.

Click Apply. A confirmation message appears.

7.

Click OK. Changes to the iSCSI target name and host mode are applied to the array.

Deleting host groups

NOTE:

You cannot perform this operation on host groups for NAS ports.