Remote path status problems

The following table provides a list of remote path status problems.

Corrective action

Description

Path status

None required.

This path has been
successfully established and

Normal

can be used for Continuous
Access Synchronous Z copy
activities.

The link initialization
procedure to the secondary

Initialization Failed

Make sure that the primary and secondary systems are
physically and correctly connected.

system failed because the

Make sure that you entered the correct secondary system
S/N, Controller ID, and primary and secondary system
port numbers.

physical path connection was
missing between the primary
and secondary system.

Make sure the primary and secondary system ports are
configured correctly.

Communication between the
primary and secondary
system timed out.

Communication Time
Out

Make sure the secondary system is powered on and that
NVS and cache are fully functional.

Make sure that network relay devices are properly
configured and functional. This includes cables, connectors,
switches, extender devices, communication lines, and all
other devices connected to the extenders.

The primary system rejected
the logical path link control

Port Rejected

Delete all paths and RCUs not in use.

Make sure that all primary and secondary system ports are
properly configured: ordinary RCU target ports for

function because all logical
path resources in the primary

Remote path status problems