HP XP7 Storage User Manual

Page 77

Advertising
background image

S-VOL access

P-VOL access

Description

BCM status

RWC status

No

Read/Write

DUPLEX (02)

Duplex

The pair is synchronized

Updates from the host to the P-VOL are duplicated in
the S-VOL.

Read Only if
Mode=20 is

Read/Write

SUSPOP (03),
SUSPOP (04),

Suspended

(See also

“Split

types”
(page 78)

.)

The pair was split by a user. The pair is not
synchronized.

SWAPPING (04),
SUSPOP (05),
SUSPER (07),
SUSPOP (0A)

ON, otherwise
No.

When you split the pair from the primary system, that
system changes the status of the P-VOL and S-VOL to
Suspended.

In Suspended status, updates to the S-VOL stop. The
storage system keeps track of updates to the P-VOL
in order to update the S-VOL when the pair is
resynchronized.

When you split the pair from the secondary system,
that system changes the status of the S-VOL to
Suspended. The primary system detects this and
changes P-VOL status to Suspended.

When you release the pair from the secondary
system, that system changes the S-VOL status to
Simplex. The primary system detects this and changes
the P-VOL status to Suspended. The pair must be
released from the primary system in order to change
P-VOL status to Simplex.

BCM split statuses initiated by the user:

SUSPOP (O3): The user split the pair from the P-VOL.

SUSPOP (04): The user split the pair from the S-VOL.
If the P-VOL is updated, it is recorded as differential
data.

SWAPPING (04): The user split the pair in the reverse
direction (S-VOL to P-VOL).

SUSPOP (05): The secondary system received a split
request from the main system and split the pair.

SUSPER (07): The user deleted the pair from the
secondary system. The main system detected this and
split the P-VOL.

SUSPOP (0A): The pair was split because the user
issued PPRC’s FREEZE command on the main system.

Read Only if
Mode=20 is

Read/Write.

Read only if
Primary

SUSPCU (06) (by
error), SUSPCU
(08), SUSPER (09),
SUSPER (50)

Suspended

(See also

“Split

types”
(page 78)

.)

If the primary system cannot keep the pair
synchronized for any reason, it changes the status
of the P-VOL and S-VOL (if possible) to Suspended.

ON, otherwise
No.

Volume Fence
Level is Data.

The pair is not synchronized.

BCM also includes the following:

SUSPCU (08): The pair was split when the main
system detected an error during the communication
with the secondary system, or detected an I/O error
during update copy.

SUSPER (09): The pair was split because the main
system detected volatilization of pair control
information on memory when power was ON (IMPL).
This error occurs when power-off status of the main
system continues beyond the backup time for the
nonvolatile memory.

SUSPER (50): The pair was split because data
mismatch between P-VOL and S-VOL was detected
during the initial copy operation. The cause of the
error is invalid track format.

Monitoring pair status, license capacity