A Pair operations using PPRC

XP7 supports IBM Peer to Peer Remote Copy (PPRC) TSO and ICKDSF commands for performing
Continuous Access Synchronous Z operations from the zSeries and S/390 host system.
PPRC commands and requirements are described in this topic. However, not all instructions for
using the commands are provided. Refer to the IBM user documentation for more information.

Overview of PPRC commands

The following operations can be performed using PPRC issued from JCL job cards:

Port configuration using Remote Web Console (cannot be done using PPRC).
You can change port type (RCU target to initiator, and so on) as part of the pair creation
operation using CESTPATH.

Add and remove remote paths between the main and target systems

Add and delete pairs

Split and resume pairs.

Display pair status and other information.

You cannot change options for remote connections, the CU, initial copy priority, or DFW to S-VOL
using PPRC commands.
The following table describes Cnt Ac-S Z operations you perform using Remote Web Console and
the corresponding TSO and ICKDSF commands.

Description

Issued to:

PPRC Commands

1

TSO

2

ICKDSF

3

RWC operation

Establishes remote paths from an MCU to an RCU. The
default RCU options are used. See

“CESTPATH

command” (page 121)

for more information.

MCU

PPRCOPY
ESTPATH

CESTPATH

4

Add RCU (and
configure ports)

Deletes all active paths between an MCU and an RCU.

MCU

PPRCOPY
DELPATH

CDELPATH

4

Delete RCU

Displays the status of all paths for the CU specified by
the DEVN parameter. Cnt Ac-S Z supports the optional

MCU

PPRCOPY
QUERY/PATHS

CQUERY/
PATHS

RCU Status

FORMAT/UNFORMAT and VOLUME/PATHS
parameters.

Creates a pair and sets the initial copy and pair options
(copy mode = synchronous only, priority = 0, CFW

P-VOL

PPRCOPY
ESTPAIR

CESTPAIR(MODE=
COPY)

Add Pair

data = Primary Volume Only, DFW to Secondary
Volume = not required). Cnt Ac-S Z supports the
optional MODE, PACE, and CRIT parameters. The
MSGREQ parameter defaults to NO.

Splits a pair. Cnt Ac-S Z supports the optional PRIMARY
parameter. See WARNING about the QUIESCE
parameter at the end of this topic.

P-VOL or
S-VOL

PPRCOPY
SUSPEND

CSUSPEND

Suspend Pair

Releases a pair from the MCU.

P-VOL

PPRCOPY
DELPAIR

CDELPAIR

Delete Pair (to MCU)

Releases a pair from the RCU.

S-VOL

PPRCOPY
RECOVER

CRECOVER

Delete Pair (to RCU)

Displays pair status of the volume. Cnt Ac-S Z supports
the optional FORMAT/UNFORMAT and
VOLUME/PATHS parameters.

P-VOL or
S-VOL

PPRCOPY
QUERY/VOLUME

CQUERY/
VOLUME

Detailed Information