Remote path status definitions – HP XP7 Storage User Manual

Page 85

Advertising
background image

2.

To check path and port information, fromthe Storage Systems tree, click Replication > Remote
Connections > Connections (To).

Check connections under View Port Condition.

Check Status and other details in the Connections (To) tab.

Remote path status definitions

The following table provides remote path status descriptions.

Definition

Status

This path has been successfully established and can be used for Continuous Access
Synchronous Z remote copy activities.

Normal

The link initialization procedure with the secondary system has failed, because the physical
path connection between either the primary and secondary system, or between the primary
system and the host, was missing.

Initialization Failed

A timeout error has occurred between the primary and secondary system.

Communication Timeout

The remote path link function has been rejected by the secondary system. All remote path
resources in the secondary system might be used for other connections.

Path Rejected

The serial number of the control unit that is connected to this remote path does not match
the serial number specified by the Add Remote Connection window.

Serial Number Mismatch

The specified port does not have the initiator attribute.

Invalid Port Mode

There are three possible causes:

RCU Port Number
Mismatch

The specified port in the secondary system is physically disconnected from the primary
system.

The port is not configured as an RCU target port.

The specified port number is not available.

Monitoring and maintaining remote connections and paths