Business continuity manager specifications – HP XP7 Storage User Manual

Page 15

Advertising
background image

Requirement

Item

Error Reporting
Communications (ERC)
software

Required for disaster recovery.

Recommended for data migration.

See

“Error reporting communications” (page 46)

for more information.

Interfaces

Remote Web Console is required.

The following RWC roles are required to operate:

- Storage Administrator (Remote Copy)

- Storage Administrator (System Resource Management)

- Storage Administrator (Provisioning)

The primary system must be LAN-attached to a Remote Web Console computer.

The secondary system should be attached using a separate LAN at the remote site.

BCM is optional.

A command device is required

See

“Business Continuity Manager specifications ” (page 15)

.

PPRC is optional. See

“PPRC specifications, restrictions ” (page 17)

.

Business Continuity Manager specifications

Pair operations may be performed using Business Continuity Manager (BCM) commands from the
host system to the storage system. With BCM commands, you can add, split, resynchronize, and
delete pairs, and monitor pair status. You can also create the Continuous Access Synchronous Z
association between primary and secondary system (add RCU).

For the correspondence between the LINK parameters (ports) and SAID values, see

“SAID

values for CESTPATH/YKBLDPTH” (page 19)

.

For corresponding PPRC functionality, see

“PPRC, BCM command comparison” (page 18)

.

Although the same Continuous Access Synchronous Z pair operations may be performed by
using Business Continuity Manager or PPRC, Business Continuity Manager and PPRC are
independent functions. Do not use Business Continuity Manager and PPRC for the same pair
operation.

For complete information, see the Business Continuity Manager User's Guide.

Options not supported by Business Continuity Manager

Not all Continuous Access Synchronous Z operation options are supported by Business Continuity
Manager. The following table shows the default values used when you run the operation using
Business Continuity Manager. Use Remote Web Console to change these options.

Default value used by BCM

Option

Operation

Disabled

2, 3

Priority

Pair creation—YKMAKE

S-VOL

1

CFW Data

DFW not required

6

DFW to S-VOL

Not Report

7

SSB[F/M-FB]

Pair split—YKSUSPND

S-VOL

7

Split Kind

Disabled

3, 4

Priority

Pair resync—YKRESYNC

Business Continuity Manager specifications

15

Advertising
This manual is related to the following products: