Item

Cnt Ac-S Z only.

Preserve Mirror Status

Preserve mirror status.

P-VOL fence level.

Fence Level

Setting Fields

Description

Item

Cnt Ac-S only.

Secondary Volume Write

Whether the S-VOL can be written to while the pair is split.

Enable: Can write to S-VOL. Available only when performing the split
operation from the pair’s primary storage system.

Disable: Prevents writing to S-VOL. Default.

Whether the P-VOL can be written to while the pair is split.

Primary Volume Write

Depend on Primary Volume Fence Level: Writing to P-VOL depends on the
Primary Volume Fence Level Setting. Default.

Disable: Prevents writing to the P-VOL. Available only when performing the
split operation from the pair’s primary storage system.

Cnt Ac-S Z only.

SSB Transfer (F/M=FB)

Whether to report SSB (sense byte) to the host. Enable/Disable (the default).
Enable is available only when performing the split operation from the pair’s
primary storage system.

Confirm window

Selected Pairs table

Description

Item

Information about volumes in the accessed system.

Local Storage System

LDEV ID: LDEV identifier.

LDEV Name: LDEV name.