SAID values for link path statistical information (REAR CL2)

SAID

Port

Packg
local

SAID

Port

Packg
local

SAID

Port

Packg
local

SAID

Port

Packg
local

X'00e0'

CLA-J

2PG
(Option)

X'00c0'

CLA-A

2PA
(Option)

X'00a0'

CL2-J

2PJ

(Basic)

X'0080'

CL2-A

2PC

(Basic)

X'00e1'

CLC-J

X'00c1'

CLC-A

X'00a1'

CL4-J

X'0081'

CL4-A

(DKA12
Basic)

(DKA02
Basic)

X'00e2'

CLE-J

X'00c2'

CLE-A

X'00a2'

CL6-J

X'0082'

CL6-A

X'00e3'

CLG-J

X'00c3'

CLG-A

X'00a3'

CL8-J

X'0083'

CL8-A

X'00e4'

CLA-K

X'00c4'

CLA-B

X'00a4'

CL2-K

X'0084'

CL2-B

X'00e5'

CLC-K

X'00c5'

CLC-B

X'00a5'

CL4-K

X'0085'

CL4-B

X'00e6'

CLE-K

X'00c6'

CLE-B

X'00a6'

CL6-K

X'0086'

CL6-B

X'00e7'

CLG-K

X'00c7'

CLG-B

X'00a7'

CL8-K

X'0087'

CL8-B

X'00f0'

CLA-L

2PH
(Option)

X'00d0'

CLA-C

2PB
(Option)

X'00b0'

CL2-L

2PK

(Option)

X'0090'

CL2-C

2PD

(Option)

X'00f1'

CLC-L

X'00d1'

CLC-C

X'00b1'

CL4-L

X'0091'

CL4-C

(DKA13
Bacic)

(DKA03
Basic)

X'00f2'

CLE-L

X'00d2'

CLE-C

X'00b2'

CL6-L

X'0092'

CL6-C

X'00f3'

CLG-L

X'00d3'

CLG-C

X'00b3'

CL8-L

X'0093'

CL8-C

X'00f4'

CLA-M

X'00d4'

CLA-D

X'00b4'

CL2-M

X'0094'

CL2-D

X'00f5'

CLC-M

X'00d5'

CLC-D

X'00b5'

CL4-M

X'0095'

CL4-D

X'00f6'

CLE-M

X'00d6'

CLE-D

X'00b6'

CL6-M

X'0096'

CL6-D

X'00f7'

CLG-M

X'00d7'

CLG-D

X'00b7'

CL8-M

X'0097'

CL8-D

-

-

-

-

-

-

X'00a8'

CL2-N

2PL

X'0088'

CL2-E

2PE

(Option)

(Option)

-

-

-

-

X'00a9'

CL4-N

X'0089'

CL4-E

-

-

-

-

X'00aa'

CL6-N

X'008a'

CL6-E

-

-

-

-

X'00ab'

CL8-N

X'008b'

CL8-E

-

-

-

-

X'00ac'

CL2-P

X'008c'

CL2-F

-

-

-

-

X'00ad'

CL4-P

X'008d'

CL4-F

-

-

-

-

X'00ae'

CL6-P

X'008e'

CL6-F

-

-

-

-

X'00af'

CL8-P

X'008f'

CL8-F

-

-

-

-

-

-

X'00b8'

CL2-Q

2PM

X'0098'

CL2-G

2PF

(Option)

(Add3)

-

-

-

-

X'00b9'

CL4-Q

X'0099'

CL4-G

-

-

-

-

X'00ba'

CL6-Q

X'009a'

CL6-G

-

-

-

-

X'00bb'

CL8-Q

X'009b'

CL8-G

-

-

-

-

X'00bc'

CL2-R

X'009c'

CL2-H

-

-

-

-

X'00bd'

CL4-R

X'009d'

CL4-H

-

-

-

-

X'00be'

CL6-R

X'009e'

CL6-H

-

-

-

-

X'00bf'

CL8-R

X'009f'

CL8-H

Planning for Basic HyperSwap function—TPC-R support

The Basic HyperSwap function, performed from TPC-R, is an IBM product for disaster recovery.