HP XP7 Storage User Manual

Page 111

Advertising
background image

Description

Error code

(SSB2)

The S-VOL is an BC Z volume.

C3B7

An internal error occurred.

C3B8

The specified S-VOL LUN is not defined; or the LUN includes a CU LDEV that is not supported by the primary
system.

C3B9

A request for an Add Pair operation was rejected because of one of the following reasons:

C3BA

The secondary system’s SSID or CU number is not supported.

Though the secondary system’s SSID or CU number is supported, the microcode of the main system device
does not support them.

The P-VOL is in online status.

C3BD

These volumes cannot be specified as a Cnt Ac-S Z S-VOL:

C3BE

BC Z S-VOL not in Suspended status

BC Z reserved volume

BC Z P-VOL in the process of reverse copy

A Cnt Ac-S Z S-VOL cannot be specified as an BC Z S-VOL, reserved volume, or P-VOL in the process of
reverse copy.

C3BF

When the P-VOL is the BC Z S-VOL, the BC Z volumes should be a one to one combination.

C3C0

A request for an Add Pair operation was rejected because the specified volume was already part of a Cnt
Ac-S Z or Cnt Ac-J Z pair (including journal volumes).

C3C7

The S-VOL is reserved; or a secondary system, S-VOL, or the path between primary system and secondary
system is in the BUSY status.

C3CA

The S-VOL is an BC Z volume.

C3CD

The DKC type of the secondary system is not supported by Cnt Ac-S Z.

C3D2

A pair cannot be created because the P-VOL is being used by Auto LUN.

C3D4

The specified S-VOL is unavailable because the connecting port cannot recognize it.

C3D6

The pair status of the S-VOL is invalid.

C3D7

The pair cannot be created because the volume specified for the S-VOL is a system volume.

C3D8

The pair cannot be created if the Cnt Ac-S Z S-VOL corresponds to any of the following:

C3D9

The volume is a THP V-VOL; the pair using the volume is a BC Z pair or a Auto LUN reserve volume.

The volume is a THP V-VOL and an addition to volume capacity is in progress, or pages are being released.

The capacity of the volume is different from the capacity of the P-VOL

The volume is initialized by BC Z

The pair cannot be created because the volume specified for the P-VOL is a system volume.

C3DA

S-VOL pair status is not Suspended or Suspended.

C3DB

The required amount of shared memory for the operation is not installed in the secondary system.

C4FC

Cnt Ac-S, Cnt Ac-S Z, Cnt Ac-J, and Cnt Ac-J Z cannot be mixed in the consistency group.

CB12

The secondary system consistency group cannot be deleted because the Takeover command reversing
operations between the P-VOL and S-VOL failed.

CB19

The secondary system consistency group was abnormally terminated because the Takeover command
reversing operations between the P-VOL and S-VOL failed.

CB1A

No dummy volume can be created in the S-VOL.

CB1D

Troubleshooting using RAID Manager

111