Requirements

•

System option mode 114 set to OFF.

•

System option mode 484 and 769 set to ON.

•

A bi-directional path between MCU and RCU must be in place.

Recommendations

•

For best performance, the maximum number of pairs for the Basic HyperSwap function is
1,000 per CHA.

•

The MIH value of host I/O and the host operation is about one second. This allows MIH to
be reported for host I/O or for the host operation.

•

Resources in the host system must be adequate. If a shortage occurs, resynchronization of
Continuous Access Synchronous Z pairs may fail.

•

When running the FREEZE command, make sure that it can complete within 20 seconds to
avoid failure. HP recommends configuring your system as follows:

◦

(Number of Host paths) x (Number of LPARs) x (Number of CGROUPs (Number of CUs))
≤ 160

◦

Number of pairs ≤ 4,096

Planning for Extended Address Volume

Extended Address Volume (EAV) can be assigned to a Continuous Access Synchronous Z pair.
EAV is a HP function to define a large capacity VOL that is not supported by existing 3390 type
volumes. You can create a pair with and/or without EAV. The following table shows EAV availability
for P-VOLs and S-VOLs.

S-VOL (Device emulation type)

P-VOL

(Device emulation type)

No EAV (3390-X

*1

)

EAV (3390-A)

Not available

Available

EAV (3390-A)

Available

Available

non-EAV (3390-X

*1

)

1. 3390-X indicates the 3390 series other than 3390-A. For these other supported 3390 emulation types, see the
table in

“System requirements and specifications” (page 13)

.

Emulation type 3390 combined with non-3390 device types is not available.

Planning for Extended Address Volume