Raid manager pair status names, Split types, Raid manager pair status names split types – HP XP7 Storage User Manual

Page 78: Split

Advertising
background image

S-VOL access

P-VOL access

Description

BCM status

RWC status

1

When pair status is Pending, neither cache nor shared memory can be added to or removed from the storage system. When

either of these tasks is to be performed, first split any pairs in Pending, status, then resynchronize when the cache or shared
memory operation is completed.

RAID Manager pair status names

RAID Manager pair status names are different than Remote Web Console status names. The
following shows the corresponding names.

RAID Manager pair status name

Remote Web Console pair status name

SMPL

Unpaired

COPY

Pending

PAIR

Duplex

PSUS

Suspended (by operation)

PSUE

Suspended (by error)

Split types

This topic discusses pairs that are split by user operation (Suspended-delete pair to RCU), and
pairs that are suspended by the system because of failure (Suspended).

You can split a pair when the initial copy operation is complete.

You must split a pair to perform ICKDSF maintenance on the P-VOL or to access the S-VOL
(read-only mode). Continuous Access Synchronous Z pairs are also split when the CGROUP
FREEZE/RUN command is processed.

When you split a pair, the primary system ensures synchronization by completing any
pending update copy operation according to the user specified drain/purge suspend
optionbefore changing the status to Suspended.

Pairs are split by the primary system only, for any of the following reasons:

You released the pair from the secondary system.

An error condition related to the secondary system, the S-VOL, or an update-copy
operation.

When the secondary system cannot run DFW (DASD fast write) to the S-VOL (when the
PPRC DFW-to-S-VOL-Required option is specified).

The primary system cannot communicate with the secondary system.

Split types appear in the Status field on the View Pair Properties window. The following table
describes the split types. (RAID Manager does not display split types.)

Description

Volume
applies to

Split type

PPRC

BCM

RWC

The user specified that the pair should be split. This
was done during the pair split operation from the

P-VOL

SUSPEND(03)

SUSPOP(03)

Primary Volume
by Operator

primary system by selecting Disable for the Primary

78

Monitoring and maintaining the Cnt Ac-S Z system

Advertising
This manual is related to the following products: