Changing p-vol fence level, cfw data – HP XP7 Storage User Manual

Page 82

Advertising
background image

Changing P-VOL Fence Level, CFW Data

You can change the P-VOL’s fence level, which specifies when to reject write operations to the
P-VOL under certain failure circumstances. You can also change whether CFW (DASD fast write)
data is copied to the S-VOL or not.

For more information on fence levels, see

“Allowing I/O to the P-VOL after a split—Fence Level

options” (page 36)

.

Prerequisite information

•

Pair status must be Pending or Duplex.

•

The Edit Pair Options window is used for the following procedure. If you select multiple pairs,
the values do not display but are blank. When you change a value, the change applies to all
selected pairs

Procedure 19 To change the fence level and CFW data options

1.

In the Storage Systems tree, click Replications > Remote Replications.

2.

Click the Cnt Ac-S Pairs tab, then select the pair whose options are to be changed.

3.

From the Actions menu, click Remote Replications > Edit Pair Options.

4.

In the Edit Pair Options window, for Primary Volume Fence Level box, select the fence level
for the pairs.

- Never: The P-VOL can always be written to.

- Data: The P-VOL cannot be written to.

- Status: The P-VOL cannot be written to only if the primary system is not able to change S-VOL
status to Suspended.

5.

For CFW Data, select whether CFW data is copied to the S-VOL.

•

- Primary Volume Only: CFW data is not copied to the S-VOL.

•

- Secondary Volume Copy: CFW data is copied to the S-VOL.

82

Monitoring and maintaining the Cnt Ac-S Z system