HP XP7 Storage User Manual

Page 106

Advertising
background image

Description

Error code (SSB2)

The command was rejected because the specified journal was already used in another Cnt Ac-J's
mirror ID.

E889

The command was rejected because of one of following:

E890

The specified volume is registered in another journal.

The specified volume is registered in the same mirror of the same journal

The volume specified as the S-VOL is registered in another mirror of the same journal.

The command was rejected because the number of pairs that are registered in the specified
master journal or restore journal was already reached the maximum number.

E891

When creating a pair using journal in the configuration where three Cnt Ac-J sites were combined,
a request of pair creation of the third mirror was received in the same journal, so the command
was rejected.

E894

The command was rejected because of the one of following reasons.

E897

The specified primary journal and the secondary journal do not permit the configuration
combining three Cnt Ac-J sites.

The specified secondary journal is already used as a secondary journal of another mirror.

The paired journal of the specified mirror is already used by another mirror.

The command was rejected because the specified secondary journal is already a secondary
journal in another mirror.

E898

The command was rejected because the path between the storage devices for the both-way was
not defined. Check whether the bidirectional normal path was defined or not.

E89A

The command was rejected because the specified master journal or the restore journal remembered
the state of connection with another system in the past. Specify another journal, or delete the
journal once, then retry the registration again.

E89B

The command was rejected because the Serial Number, Controller ID, or Path Gr. ID of the
specified secondary storage system is wrong.

E8A2

The specified journal ID is unregistered.

E8A6

Journal volume is unregistered on the specified journal.

E8A7

The command was rejected because the specified volume was not for a Cnt Ac-J pair or was a
volume of another journal.

E8A8

Cnt Ac-J copy pair cannot be suspended because of the power-on processing.

E8A9

The command was rejected because the mirror ID of the specified restore journal was already
used.

E8B6

The command was rejected because the volume in the specified journal was used for maintenance.

E8B8

The command was rejected because there are multiple journals in the specified consistency group.

E8F7

A logic error occurred in the system, and the command was rejected.

E8FB

The command was rejected because the specified P-VOL was already used as an S-VOL.

EA00

The command was rejected because the specified P-VOL was already used by another Cnt Ac-J
pair.

EA01

The command was rejected because the specified S-VOL was used as the P-VOL.

EA02

The command was rejected because the specified P-VOL was already used by another Cnt Ac-J
pair.

EA03

The command was rejected because the number of the Cnt Ac-J pair registrations in the primary
journal exceeds the upper limit.

EA07

The command was rejected because the number of Cnt Ac-J pair registrations in the secondary
journal exceeds the upper limit.

EA08

106 Cnt Ac-J troubleshooting