background image

Description

Error code (SSB2)

The command was rejected because the license capacity of the Data Retention in the secondary
system exceeds the setting value. Please check the license capacity setting for Data Retention in
the secondary system.

EBAF

The command was rejected because the specified Cnt Ac-J S-VOL was used by either Business
Copy or Compatible FlashCopy.

EBC6

The command was rejected because the journal restore operation is in progress in the Cnt Ac-J
pair through another mirror ID.

EBCA

If the Cnt Ac-J pair with another mirror ID is in Suspending status, re-issue the request when
the pair status is changed to the Suspend status.

If the Cnt Ac-J pair with another mirror ID is in the PAIR status, reissue the request after awhile.

The command was rejected because un-updated differential data exists in the specified S-VOL.

EBCE

The Cnt Ac-J Pairresync (journal resync mode that forcibly copies all data) was received because
of the Cnt Ac-J Pairresync (delta resync) failed. The command was rejected because the Cnt Ac-J
pair was not in HOLD status.

EBCF

The command was rejected because the desired capacity exceeded the charging capacity of
the secondary system's Continuous Access Synchronous. Check the license capacity as well as
the related program product.

EBD9

The command was rejected because the desired capacity exceeded the charging capacity of
the secondary system's Cnt Ac-J. Check the license capacity as well as the related program
product.

EBDB

The command was rejected because the processing load of the storage system is heavy. Please
execute the command again after a while.

EBDC

The command was rejected because the specified S-VOL was already used in the Cnt Ac-J pair
for delta resync.

EBE0

The command was rejected because the all S-VOLs of the specified restore journal were not the
another Cnt Ac-J's S-VOLs.

EBE1

The command was rejected because the difference was not ready for the journal resync operation.

EBE2

The update data of Continuous Access Synchronous (master journal of the Cnt Ac-J pair for delta
resync operation) is inconsistent with the update data of the restore journal of the Cnt Ac-J pair.
Perform Cnt Ac-J Pairresync (journal resync mode that forcibly copies all data).

The command was rejected because the journal volume of specified restore journal was blocked.

EBE5

The command was rejected because the ATTIME Suspend function is used combining Cnt Ac-J Z
with BC Z and the split time is restored to the specified restore journal.

EBF2

The command was rejected because the split time of the ATTIME Suspend function is restored.

EBF3

The command was rejected because the specified restore journal was not registered.

EBFD

Troubleshooting with RAID Manager

111