Service information messages (sims), Miscellaneous troubleshooting, Delta resync operation – HP XP7 Storage User Manual

Page 112: Suspension among journals, Delta resync operation suspension among journals, Raid manager error codes for cnt ac-j: ssb1 = b9fe

Advertising
background image

Description

Error code (SSB2)

The pair cannot be created because of one of the following conditions regarding the specified
S-VOL:

F908

Virtual access mode is disabled for the volume registered in the mirror, but is enabled for the
specified volume .

Virtual access mode is enabled for the volume registered in the mirror, but is disabled for the
specified volume.

The specified volume whose virtual access mode is enabled has an incorrect virtual system
serial number or virtual controller ID.

The pair cannot be created because of one of the following conditions regarding the specified
P-VOL:

F909

Virtual access mode is disabled for the volume registered in the journal group, but is enabled
for the specified volume .

Virtual access mode is enabled for the volume registered in the journal group, but is disabled
for the specified volume.

The specified volume whose virtual access mode is enabled has an incorrect virtual system
serial number or virtual controller ID.

RAID Manager error codes for Cnt Ac-J: SSB1 = B9FE

Description

Error code (SSB2)

Journal volumes are not registered in the specified journal.

B902

Service information messages (SIMs)

XP7 generates service information messages (SIMs) when service is required. SIMs are generated
by channel and storage path microprocessors and by .

The SVP reports all SIMs related to Continuous Access Journal processing. Each time a SIM is
generated, the amber Message LED on the control window (under the Ready and Alarm LEDs)
turns on as an additional alert for the user.

To clear Cnt Ac-J-related SIMs, contact HP Technical Support.

Miscellaneous troubleshooting

Delta resync operation

If the status of the delta resync pair does not change after you performed delta resync operation,
some of the requirements and prerequisites may not have been fulfilled. In that case, after checking
the status of all pairs including the delta resync pair for clues into the problem, review all prerequisite
material in

“Delta resync configuration ” (page 127)

.

Suspension among journals

All the journals in a consistency group can be suspended when an error occurs in one of the
journals in the consistency group. This takes place under the following conditions:

The communications line between the RAID Manager and all primary systems are normal.

The status of the failed journal is PJSE or PJSF.

At least one journal in the consistency group is in normal status.

112

Cnt Ac-J troubleshooting

Advertising
This manual is related to the following products: