Forcibly deleting pairs – HP XP7 Storage User Manual

Page 74

Advertising
background image

Procedure 20 To change pair options

1.

In the Storage Systems tree, click Replication > Remote Replication.

2.

Select the Cnt Ac-J Pairs tab, and then select the pair whos options are to be changed.

3.

From the Actions menu, click Remote Replication > Edit Pair Options.

NOTE:

When you select multiple pairs on the Cnt Ac-J Pairs tab, Edit Pair Options values

may be blank because the selected pairs have different values.

When you specify a value, it is set for all selected pairs.

4.

In the Edit Pair Options window, for Error Level, specify the system response if a failure occurs
in the pair.

•

Mirror: Splits all pairs in the failed pair’s mirror. Mirror is the default.

•

LU: Splits only the pair that failed.

5.

Click Finish.

6.

In the Confirm window, review the settings and enter a task name in the Task Name box.

7.

Click Apply to save your settings to the system.

Forcibly deleting pairs

You forcibly delete a pair for the following reasons:

•

A currently unpaired volume that was previously in a pair is unusable because previous pair
information is still in the volume.

•

The pair cannot be connected to the secondary system because of a communication error. In
this case, delete the pair forcibly in the both the primary and the secondary storage systems.

Prerequisite information

•

The volume must be unpaired.

Procedure 21 To forcibly delete a pair

1.

In the Storage Systems tree, click Logical Device.

2.

Click the LDEV tab, then select the pair that you want to delete forcibly.

74

Maintaining the Cnt Ac-J system

Advertising
This manual is related to the following products: