Procedure 20 To change pair options

1.

In the Storage Systems tree, click Replication > Remote Replication.

2.

Select the Cnt Ac-J Pairs tab, and then select the pair whos options are to be changed.

3.

From the Actions menu, click Remote Replication > Edit Pair Options.

NOTE:

When you select multiple pairs on the Cnt Ac-J Pairs tab, Edit Pair Options values

may be blank because the selected pairs have different values.

When you specify a value, it is set for all selected pairs.

4.

In the Edit Pair Options window, for Error Level, specify the system response if a failure occurs
in the pair.

Mirror: Splits all pairs in the failed pair’s mirror. Mirror is the default.

LU: Splits only the pair that failed.

5.

Click Finish.

6.

In the Confirm window, review the settings and enter a task name in the Task Name box.

7.

Click Apply to save your settings to the system.

Forcibly deleting pairs

You forcibly delete a pair for the following reasons:

A currently unpaired volume that was previously in a pair is unusable because previous pair
information is still in the volume.

The pair cannot be connected to the secondary system because of a communication error. In
this case, delete the pair forcibly in the both the primary and the secondary storage systems.

Prerequisite information

The volume must be unpaired.

Procedure 21 To forcibly delete a pair

1.

In the Storage Systems tree, click Logical Device.

2.

Click the LDEV tab, then select the pair that you want to delete forcibly.