HP XP7 Storage User Manual

Page 108

Advertising
background image

Description

Error code (SSB2)

The command was rejected because the desired capacity exceeded the charging capacity of
the secondary system's Cnt Ac-J. Check the license capacity as well as the related program
product.

EAA5

The command was rejected because the desired capacity exceeded the charging capacity of
the primary system's Continuous Access Synchronous. Check the license capacity as well as the
related program product.

EAA6

Pair creation failed because there is no available differential management area of the primary
storage system. If additional shared memory is not installed in the primary system, install it and

EAB6

then retry the operation. If additional shared memory is installed, the pair cannot be created
because the maximum number of pairs is exceeded.

The paircreate operation failed because no extended shared memory is installed in the primary
system. Install extended shared memory in the primary system and then repeat the operation.

EAB7

Pair creation failed because there is no available differential management area of the secondary
system. If additional shared memory is not installed in the secondary system, install it and then

EAB8

retry the operation. If additional shared memory is installed, the pair cannot be created because
the maximum number of pairs is exceeded.

The paircreate operation failed because no extended shared memory is installed in the secondary
system. Install extended shared memory in the secondary system and then repeat the operation.

EAB9

The pair operation failed because the shared memory is not installed in the specified LDEV number.

EABC

The command was rejected because the delta resync function was unsupported.

EAD0

The command was rejected because the specified P-VOL or S-VOL is in the process of having the
capacity changed by Thin Provisioning.

EAE5

The Cnt Ac-J pair cannot be deleted because the specified Cnt Ac-J volume is used as the
Continuous Access Synchronous pair and is working in the journal that was registered when the
2DC Cascade was set to Enable in the Edit Journal Volumes dialog box.

EAE7

The command was rejected because the pair was in the state that was unavailable to transit.

EAF6

The Cnt Ac-J pair for the delta resync operation cannot be created because the specified Cnt Ac-J
S-VOL is in either one of the following statuses:

EB24

Cnt Ac-J volume for the delta resync operation.

The status of the Cnt Ac-J pair is other than PAIR.

The Cnt Ac-J pair for delta resync operation cannot be created because the specified Cnt Ac-J
S-VOL is in either one of the following statuses:

EB25

The volume cannot be used as the Cnt Ac-J volume for the delta resync operation.

The status of the Cnt Ac-J pair is the status other than PAIR or SUSPEND.

The command was rejected because the Cont Access Journal 3DC & 4x4 Open MF program
product was not installed in the secondary system.

EB28

The command was rejected because the delta resync settings are configured to the primary and
secondary systems.

EB29

The command was rejected because shared memory for operating Cnt Ac-J is not installed.

EB2D

The command was rejected because the specified Cnt Ac-J pair was used in the system that
consists of multiple primary and secondary systems.

EB2F

The command was rejected because the specified mirror ID was invalid.

EB30

The command was rejected because the microcode is being exchanged or the micro program
exchange operation is suspended.

EB37

The specified Cnt Ac-J pair cannot execute the takeover because the specified Cnt Ac-J pair
belongs to the journal that dedicated Cnt Ac-J and Continuous Access Synchronous combination
(2DC configuration).

EB45

108 Cnt Ac-J troubleshooting

Advertising
This manual is related to the following products: