HP XP7 Storage User Manual

Page 110

Advertising
background image

Description

Error code (SSB2)

The command was rejected because the Cnt Ac-J program product was not installed in the primary
system.

EB6E

The command was rejected because the specified S-VOL is assigned to a copy pair of other
program products.

EB70

The command was rejected because the specified S-VOL is the system disk.

EB73

The command was rejected because all mainframe connection CHAs are blockaded.

EB74

The command was rejected because the specified data volume is a command device.

EB78

The command was rejected because the specified data volume is online.

EB79

The command was rejected because the journal cache of the restore journal was remained.

EB7A

The command was rejected because the specified S-VOL is an external volume.

EB7D

The command was rejected because the specified S-VOL is in one of the following statuses.

EB7E

The specified S-VOL is being used for a Business Copy pair.

The specified S-VOL is a reserved volume.

Cnt Ac-J P-VOL and S-VOL are THP V-VOL, and the specified S-VOL is being used as Business
Copy P-VOL.

Cnt Ac-J P-VOL and S-VOL are THP V-VOL, and the specified S-VOL is the source volume of
Auto LUN.

Cnt Ac-J P-VOL and S-VOL are THP V-VOL, and the specified S-VOL is being used as Fast Snap
P-VOL.

The command was rejected because the emulation type of the specified S-VOL was unsupported.

EB7F

The command was rejected because the specified volume was the V-VOL or the pool-VOL. Please
check the status of the volume.

EB80

The command was rejected because the path from the secondary system to the primary system
is not set, or the volume used as the S-VOL is not paired.

EB87

The command was rejected because of one of the following:

EB88

The specified S-VOL was being used as a Business Copy S-VOL.

The specified S-VOL was Not Ready, which means that the data drive cannot be used.

The command was rejected because the emulation types of the specified P-VOL and S-VOL were
not the same.

EB89

The command was rejected because the emulation types of the specified master journal and the
restore journal were not the same.

EB8A

The pair cannot be created because the S-VOL is in a LUSE configuration.

EB8E

The command was rejected because the specified pair could not transit the status.

EB94

The command was rejected because the specified S-VOL was not mounted on the secondary
system.

EB9F

The command was rejected because the specified S-VOL was not mounted on the secondary
system.

EBA0

The command was rejected because the volume specified for the secondary volume was in either
one of the following status.

EBA7

Increasing the capacity by Thin Provisioning.

Releasing the page of Thin Provisioning.

Initializing the pool of Thin Provisioning.

110

Cnt Ac-J troubleshooting