HP XP7 Storage User Manual

Page 96

Advertising
background image

Corrective action

Error

The pair create or pair resync operation resulted in
a timeout error.

If the timeout error was caused by a hardware failure, a SIM is
generated. See

“Service information messages (SIMs) ” (page 112)

. If

necessary, call HP Technical Support, and retry Cnt Ac-J operations
after the problem is solved.

If no SIM was generated, wait for a while (5 or 6 minutes), then check
the pair status of the pairs being created or resynchronized. If the pair
status changed correctly, the failed operation completed after the timeout
message was issued. If the pair status did not change as expected,
heavy workload might have prevented the Cnt Ac-J operation from
being completed. In this case, retry the Cnt Ac-J operation when the
system has a lighter workload.

If a time-out error occurs during the paircreate operation, the copy
operation might not have been executed correctly in the order specified
in the Priority field. A time-out error may be caused by the CU
configuration or a remote copy path error. Review the error, release
the pair with the error, and then retry the paircreate operation.

See HP XP7 Remote Web Console User Guide for instructions.

A communication error between Remote Web Console
and the SVP occurred.

The error caused the delete journal operation to suspend. Re-register the
journal volumes that belong to the journal, then delete the journal again.

Journal volumes are not registered in the journal

This is caused when the following two conditions exist:

The pairresync operation suspends with a warning
message.

The Preview list contains two or more pairs belonging to the same
mirror.

Mirror is defined in the Range column for at least one of the above
pairs.

To continue processing, do either of the following:

Ensure that the Range column displays LU for all pairs in the same
mirror.

In the Preview list, delete all but one pair in the same mirror.

The error code appears in the right-most column of the Preview list. To
view detailed information about the error, right click the error code and
select Error Detail.

An error occurs when Apply is clicked for a pair
operation.

See

“Deleting pairs in a mirror ” (page 52)

and specify Force for Delete

Mode.

The pairs cannot be deleted after the pair operations
because the pair status changed to Suspending or
Deleting.

96

Cnt Ac-J troubleshooting

Advertising
This manual is related to the following products: