Procedure for a 2dc configuration – HP XP7 Storage User Manual

Page 136

Advertising
background image

If you release the Cnt Ac-S pair when the Cnt Ac-J P-VOL is in COPY status, the Cnt Ac-J pair
becomes suspended by error.

For Cnt Ac-J, an X at the end of the device ID indicates the LDEV is a Thin Provisioning virtual
volume. However, the X does not display when both of the following conditions exist:

The Cnt Ac-S S-VOL is a Thin Provisioning virtual volume.

The Cnt Ac-J S-VOL is not a Thin Provisioning virtual volume.

Procedure for a 2DC configuration

Procedure 44 To set up a 2DC configuration

1.

Install and set up Cnt Ac-S and Cnt Ac-J on the required systems.

2.

When registering the journal on the intermediate site, set 2DC Cascade to Enable in the Edit
Journal Volumes dialog box.

3.

Create the Cnt Ac-J pair on the intermediate system.

4.

When Cnt Ac-J pair status is PAIR, create the Cnt Ac-S pair on the primary system.

5.

Confirm that Cnt Ac-S pair status becomes PAIR.