–sortcol <col>[,<dir>][:<col>[,<dir>]...]

Sorts command output based on column number (<col>). Columns are numbered from left
to right, beginning with 0. You must specify a column number.
In addition, you can specify the direction of sorting (<dir>):

inc

- Sort in increasing order (the default).

dec

- Sort in decreasing order.

-filt <fspec>

Specifies that statistics that fall below the threshold specified by the <fspec> argument are
filtered out and not displayed. To specify the <fspec> argument, use the syntax:
<type>,<op>,<meas>,<val>

. The arguments are separated by one comma.

type

- The type argument can be specified with one of the following arguments:

curs

- Specifies that only devices with current statistics above the threshold are

displayed.

avgs

- Specifies that only devices with average statistics above the threshold are

displayed.

maxs

- Specifies that only devices with maximum values above the threshold are

displayed.

op

- The operation argument can be specified with one of the following arguments:

r

- Specifies that read-only statistics are displayed.

w

- Specifies that write-only statistics are displayed.

t|rw

- Specifies that statistics for read and write totals are displayed.

meas

- The measure argument can be specified with one of the following arguments:

iops

- Specifies that I/O operations per second are displayed. If this argument is

used, the minimum threshold value must be specified using the <val> argument.

bw

- Specifies that statistics for bandwidth in bytes per second are displayed. If this

argument is used, the minimum threshold value must be specified using the <val>
argument.

svct

- Specifies that statistics for service time in milliseconds are displayed.

size

- Specifies that statistics for I/O operations in bytes are displayed.

<val>[k|K]|[m|M]|[g|G]

- Specifies the minimum threshold using any integer. The

integer can be optionally followed with k or K to indicate a multiple of 1000, m or M to
indicate a multiple of 1000000, or g or G to indicate a multiple of 1000000000.

For example, –filt curs,r,iops,10k specifies that statistics for a device that has more
than 10,000 current read-only I/O operations are displayed.

-ni

Displays statistics for non-idle devices. This option is shorthand for the option -filt
curs,t,iops,0

.

SPECIFIERS

<VV_name|pattern>...

Displays statistics only for the specified virtual volume or volume name pattern. Multiple volumes
or patterns can be repeated (for example, <VV_name> <VV_name>...). If not specified, all
virtual volumes that are configured for Remote Copy are listed.

RESTRICTIONS

None.