Verifying connectivity between systems – HP 3PAR Operating System Software User Manual

Page 58

Advertising
background image

Local Setup

(not connected to the FC
SAN)

SystemA

SystemB

Target system

RCFC links

•

•

Node WWN:
2FF70002AC0000C3

Node WWN:
2FF70002AC000060

•

•

Node 0 WWN:
20110002AC000060

Node 0 WWN:
20210002AC0000C3

•

•

Node 1 WWN:
21210002AC0000C3

Node 1 WWN:
21320002AC000060

Synchronous

Mode

Backup system 2 (SystemC) is located far from the primary system and backup system 1, and
therefore must use an IP network.

•

An IP network connects all systems. (The two backup systems use the IP network to share a
standby link for failover and recovery purposes.)

•

Replication between SystemA and SystemC is in asynchronous periodic mode.

Local + Remote Setup

Example backup system 2

Example backup system 1

Example primary system

SystemC

SystemB

SystemA

System name

SystemA

SystemA

SystemB

Target system 1

RCIP links for target system
1

•

Node 2 IP address
10.100.33.96

•

Node 2 IP address
10.100.33.96

•

Node 2 IP address:
10.100.33.195

•

•

•

Node 3 IP address:
10.101.33.195

Node 3 IP address
10.101.33.96

Node 3 IP address
10.101.33.96

SystemB

SystemC

SystemC

Target system 2

RCIP links for target system
2

•

Node 2 IP address:
10.100.33.195

•

Node 2 IP address:
10.100.33.63

•

Node 2 IP address:
10.100.33.63

•

•

•

Node 3 IP address:
10.101.33.63

Node 3 IP address:
10.101.33.195

Node 3 IP address:
10.101.33.63

Asynchronous periodic —>
SystemA

Asynchronous periodic —>
SystemC

Mode

Verifying Connectivity between Systems

Verify the connectivity for each Remote Copy pair you are configuring.

•

RCIP Remote Copy pairs:

# controlport rcip ping <IP_address> <N:S:P>

•

RCFC Remote Copy pairs:

# showrctransport -rcfc

For more information, see

“Verifying the Servers Are Connected” (page 35)

.

58

Setting Up Synchronous Long Distance Remote Copy

Advertising
This manual is related to the following products: