Quick setup: rcfc transport layer, Quick setup: remote copy configurations – HP 3PAR Operating System Software User Manual

Page 215

Advertising
background image

Quick Setup: RCFC Transport Layer

Table 3 Quick Setup Steps for RCFC

Backup System

Primary System

Reference

Step

controlport config

rcfc -ct point -f

<N:S:P>

controlport config

rcfc -ct point -f

<N:S:P>

“Setting Up the Remote
Copy Interface for RCFC”
(page 39)

1.

On all RCFC ports, set up
the interface.

showport -rcfc

showport -rcfc

2.

On all RCFC ports, get
RCFC port positions.

showrctransport -rcfc

showrctransport

-rcfc

3.

Verify links.

controlport rcfc init

-f <N:S:P>

controlport rcfc

init -f <N:S:P>

4.

On each RCFC port,
initialize port.

showrctransport -rcfc

showrctransport

-rcfc

5.

On each RCFC port,
verify port is ready

a.

checkrclink

startserver

<N:S:P>

<dest_addr>

“Checking Link Throughput
and Latency” (page 40)

6.

On all nodes, check the
links.

b.

checkrclink

startclient

<N:S:P>

<dest_addr> <time>

c.

checkrclink

stopserver <N:S:P>

Quick Setup: Remote Copy Configurations

Table 4 (page 216)

1-to-1 Unidirectional

Table 5 (page 217)

1-to-1 Bidirectional

Table 4 (page 216)

for each Remote Copy pair (4 max

primary:1 backup).

N-to-1

Table 5 (page 217)

for one Remote Copy pair if desired.

Table 4 (page 216)

for each Remote Copy pair (1 primary:2

max backup).

1-to-N

Table 5 (page 217)

for one Remote Copy pair if desired.

Table 6 (page 218)

Synchronous Long Distance

NOTE:

If you use a script to set up the Remote Copy configuration, keep in mind that after the

creatercopytarget

and admitrcopylink commands it takes some time to establish the

TCP/IP connections; it can take as long as two minutes for the links to be marked Up and the target
marked Ready.

Quick Setup: RCFC Transport Layer

215

Advertising