31.8 Troubleshooting enclosures and enclosures groups

31.8.1 Add or remove enclosure is unsuccessful

Possible cause and recommendation

Symptom

If adding an enclosure is not successful, a notification panel provides the reason why and
provides a solution to the problem. Often, the resolution is to click the add link embedded in
the message; the add action rediscovers all components and updates its knowledge of the
enclosure.

Enclosure is already being managed by some other management software
and is claimed by that software

1.

If a first-time enclosure add does not succeed, verify that the enclosures prerequisites listed
in the online help are met. Verify that the data you entered on the screen is correct, and try
the action again.

2.

Follow the guidance in the notification panel for the corrective action you need to take to
successfully add the enclosure.

Failures can occur during the add action if all information about an enclosure, its server
blades, or interconnect modules cannot be acquired. When this happens, an explanation
of the problem and the component that caused the problem (the enclosure, a server blade,
an interconnect) is provided in a notification panel.

3.

To re-add an enclosure, click the add link in the notification message panel (if there is one),
or start the add action again from the Add Enclosure screen, supplying the address and
credentials for the enclosure's Onboard Administrator.

To forcibly add the enclosure to the appliance, see the online help for enclosures.

Unable to add an
enclosure

You forcibly added an enclosure but received an error message. This happens in cases where
there is a VCMode set and HP Virtual Connect (VC) is managing the enclosure.

1.

Manual clean-up of the configuration is needed, investigate the following items:

• The management URL might still point to the appliance. If so, it needs to be reset to point

at the first interconnect in the enclosure. To fix this, use the following ssh commands to
go into the Onboard Administrator (using administrator credentials) and change the
management URL to point to the first active VC interconnect's IP address:

Disassociates the enclosures from the appliance.

clear vcmode

(where N is the bay number of a VC interconnect)
Performing this step for every VC interconnect in the
enclosure causes the interconnect to revert to a default
configuration.

restart interconnect

N

(where N is the bay number of the active Onboard
Administrator) This causes the OA to obtain the
management URL from the first VC interconnect.

restart oa N

2.

After manual configuration, see the online help for adding enclosures.

Unable to forcibly add
an enclosure

You replaced the enclosure midplane but did not follow the recommended procedure in the
hardware documentation.

Recommendation: Re-add the enclosure.

An existing enclosure
is detected as being
new after a midplane
is replaced